Engineering solutions for emissions control
Reduce pollutant emissions with our innovative products and solutions
Know moreProducts and solutions
Centralised cleaning
We calculate, design, and install vacuum conveying systems to transport any type of material over any distance required.
Description
Vacuum conveying systems can be:
- PERMANENT: For cleaning large industrial spaces.
- MOBILE: For long distances.
The size of the VACUUM UNIT depends on the number of operators working simultaneously and the amount of product to be evacuated. The cyclone PRE-SEPARATOR can be positioned to discharge the material into the process recycling system.
Cassette FILTERING UNIT, cleaned by automatically programmed compressed air or by reverse air depending on the circumstances. FILTER CONTROL protects the vacuum pump in the event of a filter rupture by sending a signal through the differential pressure gauge that cuts off the current to the pump motor.
Success stories
They have already taken the step. Now it's your turn
Viseu Portugal
- Flue Gas Flow
- 94.137 Nm3/h
- Gas Temperature
- 142ºC
- Application
- Biomasa
- Operating Data
- Dust
ARC International France
- Flue Gas Flow
- 20,000 Nm3/h
- Gas Temperature
- 400ºC
- Application
- Glass
- Operating Data
- Dust, SO2, NOx, HF
Ferroven Venezuela
- Flue Gas Flow
- 320,000 Am3/h
- Gas Temperature
- 220ºC
- Application
- Non-ferrous casting
- Operating Data
- Dust
Cepsa Spain
- Flue Gas Flow
- 17.000Nm3/h
- Gas Temperature
- 290ºC
- Application
- Petrochemistry
- Operating Data
- Dust, NOx, SO2, HCL, dioxins
Strasbourg France
- Solution
- FIVECERAMIC, reactor, storage system and convey of hydrated lime, Filter ash storage silo, ash transport system, Centrifugal fan and motor and SCR.
- Flue Gas Flow
- 47.510 Nm3/h
- Gas Temperature
- 400ºC
- Application
- Papper manufacturing
- Emission Reduction
- Particles, SO2, NOX
Huelva Spain
- Solution
- FIVEPULSE
- Flue Gas Flow
- 545.000 Am3/h
- Gas Temperature
- 70ºC
- Application
- Copper casting
- Emission Reduction
- Particles, SO2
Galicia Spain
- Solution
- VIA HUMEDA. VENTURI
- Flue Gas Flow
- 19.000 Am3/h
- Gas Temperature
- 90ºC
- Application
- Silico-ferro manganese manufacturing
- Emission Reduction
- Particles
Basque Country Spain
- Solution
- RTO
- Flue Gas Flow
- 90.000 nm3/h
- Gas Temperature
- 130ºC
- Application
- Copper recycling
- Emission Reduction
- VOC’S, CO
Navia Spain
- Solution
- SNCR
- Flue Gas Flow
- 235.000 Nm3/h
- Application
- BIOMASS
- Emission Reduction
- NOx
Mérida Spain
- Solution
- SNCR
- Flue Gas Flow
- 125.900 Nm3/h
- Application
- BIOMASS
- Emission Reduction
- NOx
Navarre Spain
- Solution
- FIVEPULSE
- Flue Gas Flow
- 230.000 Nm3/h
- Gas Temperature
- 130ºC
- Application
- Graphite electrode production
- Emission Reduction
- Particles
Ciudad Real Spain
- Solution
- Cyclone pre-separator, bag filter, lime storage and injection sistema, ash trasnport and storage silo, centrifugal fan.
- Flue Gas Flow
- 180.000 Nm3/h
- Gas Temperature
- 150ºC
- Application
- BIOMASS
- Emission Reduction
- Particles, Sox, HCL
Huelva Spain
- Solution
- Cyclone pre-separator, bag filter, lime storage and injection sistema, ash transport and storage silo, centrifugal fan.
- Flue Gas Flow
- 180.000 Nm3/h
- Gas Temperature
- 150ºC
- Application
- BIOMASS
- Emission Reduction